Start with what the manufacturer intends the product to do

A device name or sales category does not determine the regulatory route. Qualification begins with the intended medical purpose, principal mode of action, users, patient population, use environment and claims.

01

Non-invasive products

Simple does not mean unregulated

Dressings, supports, collection systems, accessories and other non-invasive products still require documented qualification, classification, risk management, evidence, labeling and market-specific records.

02

Active equipment

Energy, monitoring and treatment change the risk analysis

Diagnostic equipment, therapeutic systems, monitors, pumps and electrically powered devices require attention to active-device rules, electrical safety, electromagnetic compatibility, usability and software where applicable.

03

Invasive and implantable products

Contact, duration and anatomy drive classification

Invasiveness, contact site, duration, biological effect, absorption and interaction with medicinal substances can materially change the class, conformity assessment and clinical-evidence burden.

Implantable-device services
04

Software and connected systems

Information can itself create medical risk

Standalone software, embedded software, connected functions and AI-enabled features need a defined regulatory boundary, software lifecycle controls, cybersecurity evidence and claim-aligned validation.

Medical-software services

In vitro diagnostic medical devices follow the separate IVDR framework in the European Union. See the dedicated IVD regulatory services page.

Resolve the regulatory architecture before verification begins

These decisions determine which requirements, studies, quality processes, submissions and external reviewers belong in the development plan.

  1. 01

    What is the exact intended purpose?

    Define the medical purpose, target population, users, use environment, indications, limitations and principal mode of action.

  2. 02

    Which regulatory category and class apply?

    Document qualification, classification rule or FDA product code, applicable controls and any borderline considerations.

  3. 03

    Which evidence is needed?

    Translate claims and risks into verification, validation, biocompatibility, electrical, software, usability, cybersecurity and clinical evidence.

  4. 04

    Which external route is required?

    Confirm notified-body involvement, FDA submission type, authorised representative needs and authority interactions.

  5. 05

    How will the product be maintained?

    Plan change control, suppliers, complaints, vigilance, PMS, cybersecurity updates, registrations and evidence updates from the outset.

Build the MDR route from intended purpose and inherent risk

Regulation (EU) 2017/745 divides devices into classes I, IIa, IIb and III. The applicable Annex VIII rule, device features and claims determine both the class and the available conformity-assessment routes.

ILower risk

Class I

Non-sterile, non-measuring class I devices that are not reusable surgical instruments can generally be self-declared. The manufacturer still needs complete technical documentation and an effective quality system.

Is · Im · IrSpecific aspects

Class I with notified-body involvement

A notified body assesses the sterile, measuring or reusable-surgical- instrument aspects within the scope defined by the MDR.

IIa · IIbMedium to higher risk

Classes IIa and IIb

Notified-body conformity assessment is required. The route and depth of technical-documentation assessment depend on the class, device group, technology and selected conformity-assessment annex.

IIIHighest risk

Class III

Class III devices require notified-body assessment of the QMS and technical documentation, with the most demanding clinical and lifecycle evidence and additional procedures for certain device categories.

Qualification and class QMS and technical documentation Conformity assessment Declaration and CE marking Registration and lifecycle control
Non-EU manufacturers

A manufacturer established outside the Union must appoint a sole EU authorised representative for devices of the same generic device group.

EUDAMED

The first four declared-functional EUDAMED modules have been mandatory since 28 May 2026, including actor and UDI/device registration modules.

Lifecycle

PMS, vigilance, clinical evaluation, PMCF where applicable and risk management must remain connected after the CE mark is affixed.

Identify the FDA product code before choosing the submission

FDA class alone does not identify the complete pathway. The classification regulation, product code, intended use, technology, predicates and exemption limitations determine the applicable controls and premarket route.

Exempt

No premarket submission where the exemption applies

An exemption from 510(k) does not by itself remove applicable general controls or other requirements. Confirm the exact classification regulation and the limitations of exemption before relying on this route.

510(k)

Substantial equivalence to a legally marketed predicate

The submission must support the intended use, technological comparison, performance testing and substantial-equivalence conclusion for the proposed device.

De Novo

Novel low-to-moderate-risk device type

De Novo provides a classification route when no legally marketed predicate exists and general controls alone, or general and special controls, can reasonably assure safety and effectiveness.

PMA

High-risk devices requiring premarket approval

PMA requires valid scientific evidence supporting reasonable assurance of safety and effectiveness, together with manufacturing and quality information.

01

Classification and controls

Confirm the product code, class, regulation, general controls, special controls and submission status.

02

Evidence and FDA interaction

Plan performance and clinical evidence, predicate strategy and Pre-Submission interaction where useful.

03

QMSR readiness

The FDA Quality Management System Regulation became effective on 2 February 2026 and incorporates ISO 13485:2016 by reference.

04

Registration and lifecycle duties

Complete establishment registration and device listing when applicable and maintain reporting, corrections, removals and quality obligations.

FDA establishment registration and device listing do not constitute clearance or approval. When a premarket submission is required, the appropriate clearance, grant or approval must be obtained before marketing.

Make one evidence system serve development and market access

A reusable evidence core reduces duplication only when product identity, configurations, claims, risks and acceptance criteria remain controlled.

01

Product definition

Intended purpose, indications, users, patients, principles of operation, configurations, accessories and market claims.

02

Risk management

Hazard analysis, benefit-risk conclusions, risk controls, verification links and residual-risk communication throughout the lifecycle.

03

Design verification and validation

Bench performance, biological safety, electrical safety, EMC, sterilization, packaging, usability, software and cybersecurity as applicable.

04

Clinical evidence

Clinical evaluation or FDA clinical strategy tied to intended purpose, claims, state of the art, residual risks and evidence gaps.

05

Manufacturing and quality controls

Controlled processes, suppliers, specifications, validation, release, nonconformity, CAPA and change management.

06

Post-market system

Complaints, PMS, vigilance or medical device reporting, trend analysis, PMCF where applicable and evidence updates.

Move from an uncertain product route to a controlled submission programme

MDRC can resolve one regulatory question or coordinate the complete route with your engineering, quality, clinical, laboratory and commercial teams.

  1. 01

    Define the product

    Confirm intended purpose, variants, accessories, users, claims, markets and regulatory boundaries.

  2. 02

    Set the strategy

    Document qualification, classification, submission or conformity-assessment route, stakeholders and critical assumptions.

  3. 03

    Assess readiness

    Review existing QMS, technical documentation, testing, clinical evidence, labeling and registrations against the selected route.

  4. 04

    Close evidence gaps

    Prepare requirements, study plans, protocols, documentation and supplier inputs needed for a reviewable dossier.

  5. 05

    Manage external review

    Support notified-body or FDA interactions, submission questions, remediation and controlled evidence updates.

  6. 06

    Maintain market compliance

    Integrate PMS, vigilance, reporting, registrations, change assessment and periodic evidence review.

Practical market-access distinctions

The exact route must be confirmed against the released device, intended use, technology, risk, evidence and target-market requirements.

Does every medical device need a notified body in the EU?

No. A class I device that is not sterile, does not have a measuring function and is not a reusable surgical instrument can generally be self-declared. Classes IIa, IIb and III and the relevant aspects of class Is, Im and Ir devices require notified-body involvement.

Does every medical device require an FDA 510(k)?

No. Depending on the product code and classification regulation, a device may be exempt, use 510(k), follow De Novo or require PMA. Exemption limitations and other applicable controls must still be checked.

Is FDA registration the same as clearance or approval?

No. Establishment registration and device listing do not constitute FDA clearance or approval. A required premarket clearance, grant or approval must be obtained before marketing.

Can one technical file support the EU and US?

A controlled evidence core can often support both markets, but dossier structure, classification, labeling, regulatory decisions and market-specific records differ. Plan reuse before assembling the submissions.

When should regulatory strategy begin?

Before intended purpose, design inputs, claims and verification plans are fixed. Early pathway decisions reduce unsuitable testing, missing evidence and late redesign.