Choose the registration route before preparing the dossier

National registration and the EAEU procedure serve different market strategies. We connect target markets, the applicant, classification, testing, examination and the device lifecycle in one regulatory plan.

Until 31 December 2027, an application may be filed under Union law or the legislation of a selected Member State. The decision should be based on project geography and evidence readiness, not only the expected filing date.

Transition periodUntil 31.12.2027 Common market5 Member States Core procedureDecision No. 46

The transition period has been extended, but the routes are not interchangeable

31.12.2027

Until this date, an application may be filed under the national rules of a Member State or under the EAEU rules. A national certificate does not provide automatic access to the other Union markets.

EEC notice on the extension

Start with the market, not the document list

Select the situation closest to your project. The result provides a working direction for an initial discussion and does not replace a product-specific assessment.

RU · One market

Compare the national and Union procedures across the entire project horizon

If the commercial plan is limited to Russia, the national route may remain practical during the transition period. The EAEU route may be preferable if later expansion to other Member States is part of the strategy.

Launch timelineEvidence readinessPlans beyond 2027
EAEU · Several markets

Design the dossier around the reference state and recognition

For access to several Member States, the project follows the Union procedure, identifies a reference state and defines the recognition states. Classification, the applicant, testing, languages and the response calendar should be aligned early.

Reference stateRecognition statesSingle version control
RU → EAEU · Transition management

Check certificate status and the gap between the two dossiers

An existing national certificate does not convert into a Union registration automatically. Its status, planned changes, source reports and potential reuse of evidence in a separate EAEU procedure should be assessed first.

Certificate statusChange planReuse of evidence

The same device may require different project decisions

This comparison shows the essential differences. The exact dossier, testing and examination requirements depend on the applicable rules and the particular device.

National routeOne market

Registration under the Russian rules

Geography

Russian Federation

Procedure

National rules and a national dossier

Outcome

National registration certificate

Limit

No automatic recognition in other EAEU states

Union routeSelected markets

Registration under the EAEU rules

Geography

Reference state and recognition states

Procedure

EEC Council Decision No. 46 and a common dossier

Outcome

Union registration for the agreed territorial scope

Condition

Coordinated examination and recognition of the results

Manage one project from qualification to the register

Support may cover an individual stage or the full route. At the outset, we define responsibilities, inputs, control points and the boundaries of MDRC decisions.

01

Route and classification

Product status, risk class, nomenclature code, grouping of modifications and selection of the applicable procedure.

02

Applicant and states

Representation model, reference state, recognition states and the regulatory calendar.

03

Evidence assessment

Review of reports, standards, clinical evidence, software documentation and operating documents.

04

Testing programme

Rationale for technical, biological, clinical or clinical-laboratory studies that may be required.

05

Dossier and examination

Controlled dossier assembly, translations, filing, responses to requests and resolution of findings.

06

Product lifecycle

Changes, safety monitoring, data updates and continued consistency across the selected markets.

Bring parallel workstreams into one controlled route

Some stages overlap, but each should close with a traceable decision before the project passes its next control point.

01

Define the device

Intended purpose, modifications, manufacturing sites, class and nomenclature code.

02

Select the architecture

Applicant, reference state, recognition states and required language versions.

03

Close the gaps

Missing evidence, testing, clinical data and quality-system readiness.

04

File the dossier

Control of completeness, fees, document versions and official communications.

05

Pass examination

Coordination of responses, supplements and agreement of the expert report.

06

Obtain recognition

Completion in the selected states and preparation for placing the device on the market.

Do not commission repeat studies before assessing existing data

A European report is not automatically accepted, but its existence also does not mean that every study must be repeated. We first compare the claims, methods, samples, laboratories, standards and requirements of the selected procedure.

Technical documentation services
Technical

Safety, performance, electrical and other applicable tests

Assess
Biological

Materials, contact, toxicological assessment and biocompatibility programme

As applicable
Clinical

Clinical or clinical-laboratory evidence according to the device type

Justify
Software

Verification, validation, risk management and cybersecurity

By technology
Metrological

Requirements for devices classified as measuring instruments

Check status
Manufacturing

Quality-system and site readiness for assessment or inspection

By class and rules

Define the representative’s authority before the first official communication

For a foreign manufacturer, the applicant and authorised representative model affects filing, responses, changes, safety monitoring and continuity of the device on the market.

01

Authority

We check the agreement, territories, device categories and authority to act in the procedure.

02

Communications

We define the authority channel, internal approval times and control of official responses.

03

After registration

We organise changes, safety communications and continued availability of current documentation.

Provide the facts needed for the first route decision

A complete dossier is not required for the initial assessment. Structured source information and a list of known constraints are sufficient to begin.

Product

Intended purpose, models, accessories, software functions and manufacturing sites

Markets

Target states, intended launch sequence and the commercial planning horizon

Status

Certificates, existing registrations, pending changes and previous authority correspondence

Evidence

Test reports, clinical data, standards, risk management and quality-system information

Registration in Russia and the EAEU

Can an application still be filed under the Russian national rules in 2026?

Yes. The protocol signed by the EAEU Member States allows applications to be filed under Union law or the legislation of a selected Member State until 31 December 2027. National registration provides access to that national market and does not automatically become registration throughout the EAEU.

Is a Russian national registration certificate valid in every EAEU country?

No. A national registration certificate operates within the national regime of the relevant Member State. For coordinated access to several countries, registration under the EAEU rules should be assessed, with a reference state and recognition states selected for the procedure.

Must all five EAEU Member States be included from the start?

No. Target states are selected according to the commercial strategy and the applicable recognition procedure. The registration plan should define the reference state, the initial recognition states and any intended later extension.

Is a CE certificate sufficient for registration in Russia or the EAEU?

No. A CE certificate and European technical documentation may provide important source material, but they do not replace the applicable registration procedure, dossier, testing and examination required under the national or EAEU rules.

Must testing always be repeated in the EAEU?

Not for every device and not to the same extent. The plan depends on the device type, risk class, claimed characteristics, applicable requirements and suitability of existing reports. Existing evidence and the rules for acceptance of results should be assessed before commissioning new studies.

Align markets and evidence before spending on the dossier

Tell us the device type, manufacturer, target states, current certificates and intended launch date. We will propose the work sequence and identify the decisions that should be made first.

Discuss registration