Continuous intake
Define the sources, owners, transfer format and controls for data completeness.
Complaints · incidents · sales · literature · PMCF or PMPFMDR · IVDR · Day-to-day data management
We turn fragmented market experience into a controlled process with defined data owners, review intervals, escalation criteria and documented decisions.
MDRC can establish the PMS operating model, perform agreed activities or support individual reporting cycles. The manufacturer retains responsibility and approves decisions while we provide the method, analysis and traceable outputs.
Service scope
Support may begin with one reporting cycle or extend to the regular operation of the complete process. Boundaries and authority are documented before work starts.
Review of data coverage, responsible functions, transfer frequency and links to specific devices.
Common categories, required fields, deduplication, exposure links and quality control of records.
Periodic evaluation of trends, deviations, severity, expectedness and possible benefit-risk impact.
Agenda, inputs, conclusions, actions, owners, deadlines and the basis for closing each issue.
Preparation or update of the PMS plan, PMS report, PSUR and related reviews using verifiable records.
Transfer of conclusions into risk management, clinical or performance evaluation, CAPA, labelling and technical documentation.
Working dataset
What do the new data change in the known safety, performance and benefit-risk profile of this device?
We do not merely place data sources next to each other. Records are linked to a device model or group, market, period, exposure, known hazards and previous actions. This structure helps distinguish an isolated case from a recurring signal and shows why a particular decision was reached.
Routing
The next action should be timely, reproducible and based on predefined criteria.
The record enters the aggregated analysis and is reassessed at the next defined review.
Additional review addresses data quality, causality, trend, exposure and links to known risks.
The applicable vigilance, CAPA, FSCA or urgent safety and documentation assessment is initiated.
Periodic outputs
Document frequency depends on the Regulation and device class. Material information is nevertheless assessed when it arrives, not only when the PMSR or PSUR is due.
The PMS report is updated when necessary.
The PSUR is updated at least every two years.
The PSUR is updated at least annually.
The PMS report is updated when necessary.
The PSUR is updated at least annually.
Controlled outputs
The package depends on the agreed scope and maturity of the system. Every document should be supported by identifiable inputs and lead to a specific conclusion or action.
Coverage, owners, frequency, format and completeness controls.
Normalized records linked to the device, period and exposure.
Signals considered, decisions, rationale, actions and deadlines.
Methods, indicators, thresholds, responsibilities and process interfaces.
Consolidated results, the benefit-risk conclusion and the status of required action.
Affected documents, change owners and evidence of completion.
Starting the engagement
We first capture the actual data flow and the nearest regulatory output. Gaps are then addressed in an order that preserves the continuity of PMS.
Devices, markets, classes, certificates, reporting periods and responsible persons.
Sources, record quality, timelines, current procedures and open actions.
Regular reviews, escalation thresholds, record format and urgent communication routes.
A priority review, report or remediation package with an agreed continuation plan.
Role boundaries
Provides access to complete data, approves procedures and conclusions, makes decisions and implements regulatory and corrective actions.
Organises and analyses data, prepares controlled outputs, identifies limitations and escalates matters to the responsible persons in time.
Connected processes
PMS does not end when a report is issued. Material information must reach the relevant part of the quality system and technical documentation.
Regulatory basis
Articles 83–86 and Annex III for medical devices
Articles 78–81 and Annex III for IVDs
Guidance on the PMS system, plan and principal activities
Guidance on the PSUR under the MDR
Questions and answers on vigilance terms and procedures
Questions in practice
Defined PMS processes and tasks may be assigned to an external provider when responsibilities, access to data and control of the outputs are clear. Regulatory responsibility for the PMS system and decisions concerning the device remains with the manufacturer.
Yes. The requirement to maintain a PMS system proportionate to the device applies to every class. For class I devices under the MDR and class A and B IVDs under the IVDR, the results are documented in a PMS report that is updated when necessary.
No. The PSUR is a periodic output of the system, not a substitute for it. Data must be collected and evaluated continuously, and material signals, incidents and the need for corrective action cannot wait until the next reporting date.
The dataset is determined by the device and its PMS plan. It commonly includes complaints and feedback, incidents and undesirable effects, information from distributors and importers, sales and usage data, literature, information on similar devices, PMCF or PMPF, and the results of corrective actions.
An ad hoc assessment is needed when new information may change conclusions on safety, performance or the benefit-risk determination, or indicates a new risk, a trend, insufficient risk controls, or a need for corrective or preventive action.
Start with the actual data flow
Tell us the device types and classes, markets, next reporting deadline, available data sources and open questions. We will propose a support scope and the first controlled output.
Discuss the PMS operating model